#iNet-600 Standalone USB data acquisition system, 16se/8di voltage inputs, 4 digital i/o, direct to sensor32
#iNet-601 Same as above, yet with bank electrical isolation31

STARTER CARD CAGE SYSTEM

#iNet-555 Starter System, includes i240, i400, i410, i430, i312.8, i510
** OUT OF STOCK **
#iNet-555.eu Same as iNet-555 described above, yet w/ 2 prong European plug
** OUT OF STOCK **

i4xx CARDS

#iNet-410 Interface between i2x0 ctlr & i4xx card cage, includes 3m Cable
#iNet-420 20se/10di voltage input, multiplexor, 4 digital i/o
#iNet-423 6di voltage input, amplifier, filter, 4 digital i/o
#iNet-430 16bit A/D, 16se/8di voltage input, mux, 4 voltage out, 4 digital i/o
** OUT OF STOCK **
#iNet-460 28 digital i/o channels

i4xx CARD CAGE

#iNet-400 Card Cage for i4xx Cards, 4 slots, expandable, includes hardware
** OUT OF STOCK **

i4xx WIRING ACCESSORIES

#iNet-510 Wiring Box with Screw Terminals
#iNet-511 BNC Wiring Box with Screw Terminals
#iNet-512 Sensor Wiring Box with Screw Terminals
#iNet-Hd44mf-3m Cable, Hd44m to Hd44f, N to N, foil shield, 26 awg, 3m (10ft)

i500 ANTI-ALIASING FILTER DAUGHTERBOARDS

#iNet-500-380Hz Fc=380 Hz Package of two (i.e. 2 channels) analog i500 filter daughterboards, 8-Pole, Butterworth
#iNet-500-1KHz Fc=1 KHz Same as above
#iNet-500-3300Hz Fc=3.3 KHz Same as above
#iNet-500-10KHz Fc=10 KHz Same as above

i100 DATA ACQUISITION BOXES
Each i100 box provides 16se/8di Analog Inputs, 8 Analog Outputs, and 8 Digital I/O lines; and includes Db25 Male to Female 3 meter Cable. The "HC" model is commended for strain gages, thermistors, RTD's, Load Cells, and Pots.

#iNet-100 instruNet External A/D Box with 3m cable
#iNet-100B Same as above, yet with additional 16 BNC Connectors
#iNet-100HC Same as iNet-100, yet with 15mA/.01uF voltage output channels

i2x0 CONTROLLER CARDS
Each Controller card manages up to eight i100/i4xx Devices; and includes an instruNet Terminator and instruNet software.

#iNet-240 USB Device for Windows ≥ XP Sp3, without iW+.
Requires computer with 1 free USB ≥ 2.0 High Speed port
#iNet-200 PCI-Bus Card for Windows ≥ Xp, without iW+.
Requires computer with 1 free PCI slot
#iNet-230 PCMCIA-Bus Card for Windows ≥ Xp, without iW+.
Requires computer with free PCMCIA slot & i312.8 supply
#iNet-240P Same as iNet-240, yet includes PLUS (iW+) software

OPTICAL ISOLATION

#iNet-330 Optical Isolator between i2x0 controller and i4xx/i100. Requires Additional i312.8 power supply, sold separately.

POWER SUPPLIES

#iNet-312.8 Power Supply, 110/220VAC, 5V/3.5A, +12V/1.5A, -12V/0.8A, USA plug, CE. Includes one i300 power adaptor cable to cable power to instruNet network. Use one 312.8 per 3 add'l 100HC via 1 i300/330/230. Use one 312.8 per 4 add'l 100 via 1 i300/330/230
#iNet-312.8eu Same as i312.8 described above, yet w/ 2 prong European plug

SOFTWARE

#iNet-350
- i2x0/i60x Serial#
instruNet World PLUS (iW+) Software License for one i2x0/i60x. One must include serial number of i2x0/i60x when ordering iNet-350, as noted here.

MOUNTING BRACKETS

#iNet-530 Wall & DIN Rail Mounting Kit for one i4xx Card Cage
#iNet-340 DIN Rail Mounting Brackets for one i100 Device

SHUNT RESISTORS

#iNet-R-33 33 Ω, Package of 8 resistors, 0.05% accuracy, 5ppm/°C drift
#iNet-R-120 120 Ω, Package of 8
#iNet-R-350 350 Ω, Package of 8
#iNet-R-1K 1000 Ω, Package of 8
#iNet-R-3300 3300 Ω, Package of 8
#iNet-R-10K 10K Ω, Package of 8
#iNet-R-33K 33K Ω, Package of 8

Db25 Cables

#iNet-Db25-3ft instruNet i2x0 Controller Cable, Db25m to Db25f, 3ft (1m)
#iNet-Db25-10ft Same as above, yet 10ft (3.0m)
#iNet-Db25-25ft Same as above, yet 25ft (7.6m)
#iNet-Db25-50ft Same as above, yet 50ft (15.2m)
#iNet-Db25-100ft Same as above, yet 100ft (30.5m)