±0.009 Kg SensorVoltageMeasureMaxEr=0.00735 Kg VexcVoltageReadbackMaxEr=0.00183 Kg LeakageCurrentThruRsrcMaxErr=0.00027 Kg AmountOfErrorThatIsNoise=58%
72.40K
±10mV Exc=3.3V
0.0018
0.0005
0 mSec
48 KHz
±0.029 Kg SensorVoltageMeasureMaxEr=0.02725 Kg VexcVoltageReadbackMaxEr=0.00183 Kg LeakageCurrentThruRsrcMaxErr=0.00027 Kg AmountOfErrorThatIsNoise=86%
72.40K
0.0084
0.0005
4 KHz
±0.004 Kg SensorVoltageMeasureMaxEr=0.00233 Kg VexcVoltageReadbackMaxEr=0.00186 Kg LeakageCurrentThruRsrcMaxErr=0.00027 Kg AmountOfErrorThatIsNoise=9%
0.78K
0.0001
0.0002
1.0 mSec
25 Kg 350Ω, 2mV/V
0 to 25 Kg
4 KHz
±0.024 Kg SensorVoltageMeasureMaxEr=0.01839 Kg VexcVoltageReadbackMaxEr=0.00457 Kg LeakageCurrentThruRsrcMaxErr=0.00066 Kg AmountOfErrorThatIsNoise=58%
72.40K
±10mV Exc=3.3V
0.0045
0.0013
0 mSec
48 KHz
±0.073 Kg SensorVoltageMeasureMaxEr=0.06814 Kg VexcVoltageReadbackMaxEr=0.00457 Kg LeakageCurrentThruRsrcMaxErr=0.00066 Kg AmountOfErrorThatIsNoise=86%
72.40K
0.0211
0.0013
4 KHz
±0.011 Kg SensorVoltageMeasureMaxEr=0.00583 Kg VexcVoltageReadbackMaxEr=0.00465 Kg LeakageCurrentThruRsrcMaxErr=0.00066 Kg AmountOfErrorThatIsNoise=9%
0.78K
0.0004
0.0004
1.0 mSec
100 Kg 350Ω, 2mV/V
0 to 100 Kg
4 KHz
±0.094 Kg SensorVoltageMeasureMaxEr=0.07355 Kg VexcVoltageReadbackMaxEr=0.01828 Kg LeakageCurrentThruRsrcMaxErr=0.00265 Kg AmountOfErrorThatIsNoise=58%
72.40K
±10mV Exc=3.3V
0.0181
0.0054
0 mSec
48 KHz
±0.293 Kg SensorVoltageMeasureMaxEr=0.27254 Kg VexcVoltageReadbackMaxEr=0.01828 Kg LeakageCurrentThruRsrcMaxErr=0.00265 Kg AmountOfErrorThatIsNoise=86%
72.40K
0.0845
0.0054
4 KHz
±0.045 Kg SensorVoltageMeasureMaxEr=0.02333 Kg VexcVoltageReadbackMaxEr=0.01859 Kg LeakageCurrentThruRsrcMaxErr=0.00265 Kg AmountOfErrorThatIsNoise=9%
0.78K
0.0014
0.0018
1.0 mSec
250 Kg 350Ω, 2mV/V
0 to 250 Kg
4 KHz
±0.236 Kg SensorVoltageMeasureMaxEr=0.18387 Kg VexcVoltageReadbackMaxEr=0.04570 Kg LeakageCurrentThruRsrcMaxErr=0.00663 Kg AmountOfErrorThatIsNoise=58%
72.40K
±10mV Exc=3.3V
0.0454
0.0134
0 mSec
48 KHz
±0.734 Kg SensorVoltageMeasureMaxEr=0.68136 Kg VexcVoltageReadbackMaxEr=0.04570 Kg LeakageCurrentThruRsrcMaxErr=0.00663 Kg AmountOfErrorThatIsNoise=86%
72.40K
0.2112
0.0134
4 KHz
±0.111 Kg SensorVoltageMeasureMaxEr=0.05834 Kg VexcVoltageReadbackMaxEr=0.04649 Kg LeakageCurrentThruRsrcMaxErr=0.00663 Kg AmountOfErrorThatIsNoise=9%
0.78K
0.0035
0.0045
1.0 mSec
1000 Kg 350Ω, 2mV/V
0 to 1K Kg
4 KHz
±0.945 Kg SensorVoltageMeasureMaxEr=0.73549 Kg VexcVoltageReadbackMaxEr=0.18279 Kg LeakageCurrentThruRsrcMaxErr=0.02652 Kg AmountOfErrorThatIsNoise=58%
72.40K
±10mV Exc=3.3V
0.1814
0.0536
0 mSec
48 KHz
±2.935 Kg SensorVoltageMeasureMaxEr=2.72541 Kg VexcVoltageReadbackMaxEr=0.18279 Kg LeakageCurrentThruRsrcMaxErr=0.02652 Kg AmountOfErrorThatIsNoise=86%
72.40K
0.8447
0.0536
4 KHz
±0.446 Kg SensorVoltageMeasureMaxEr=0.23334 Kg VexcVoltageReadbackMaxEr=0.18595 Kg LeakageCurrentThruRsrcMaxErr=0.02652 Kg AmountOfErrorThatIsNoise=9%
0.78K
0.0140
0.0179
1.0 mSec
5000 Kg 350Ω, 2mV/V
0 to 5K Kg
4 KHz
±4.724 Kg SensorVoltageMeasureMaxEr=3.67743 Kg VexcVoltageReadbackMaxEr=0.91393 Kg LeakageCurrentThruRsrcMaxErr=0.13260 Kg AmountOfErrorThatIsNoise=58%
72.40K
±10mV Exc=3.3V
0.9071
0.2682
0 mSec
48 KHz
±14.673 Kg SensorVoltageMeasureMaxEr=13.62696 Kg VexcVoltageReadbackMaxEr=0.91393 Kg LeakageCurrentThruRsrcMaxErr=0.13260 Kg AmountOfErrorThatIsNoise=86%
72.40K
4.2236
0.2682
4 KHz
±2.229 Kg SensorVoltageMeasureMaxEr=1.16672 Kg VexcVoltageReadbackMaxEr=0.92973 Kg LeakageCurrentThruRsrcMaxErr=0.13260 Kg AmountOfErrorThatIsNoise=9%
0.78K
0.0702
0.0894
1.0 mSec
100 Kg 500Ω, 2mV/V
0 to 100 Kg
4 KHz
±0.096 Kg SensorVoltageMeasureMaxEr=0.07355 Kg VexcVoltageReadbackMaxEr=0.01828 Kg LeakageCurrentThruRsrcMaxErr=0.00379 Kg AmountOfErrorThatIsNoise=57%
72.40K
±10mV Exc=3.3V
0.0181
0.0054
0 mSec
48 KHz
±0.295 Kg SensorVoltageMeasureMaxEr=0.27254 Kg VexcVoltageReadbackMaxEr=0.01828 Kg LeakageCurrentThruRsrcMaxErr=0.00379 Kg AmountOfErrorThatIsNoise=86%
72.40K
0.0845
0.0054
4 KHz
±0.046 Kg SensorVoltageMeasureMaxEr=0.02333 Kg VexcVoltageReadbackMaxEr=0.01859 Kg LeakageCurrentThruRsrcMaxErr=0.00379 Kg AmountOfErrorThatIsNoise=9%
0.78K
0.0014
0.0018
1.0 mSec
100 Kg 1000Ω, 2mV/V
0 to 100 Kg
4 KHz
±0.099 Kg SensorVoltageMeasureMaxEr=0.07355 Kg VexcVoltageReadbackMaxEr=0.01828 Kg LeakageCurrentThruRsrcMaxErr=0.00758 Kg AmountOfErrorThatIsNoise=55%
72.40K
±10mV Exc=3.3V
0.0181
0.0054
0 mSec
48 KHz
±0.298 Kg SensorVoltageMeasureMaxEr=0.27254 Kg VexcVoltageReadbackMaxEr=0.01828 Kg LeakageCurrentThruRsrcMaxErr=0.00758 Kg AmountOfErrorThatIsNoise=85%
72.40K
0.0845
0.0054
4 KHz
±0.050 Kg SensorVoltageMeasureMaxEr=0.02333 Kg VexcVoltageReadbackMaxEr=0.01859 Kg LeakageCurrentThruRsrcMaxErr=0.00758 Kg AmountOfErrorThatIsNoise=9%